Go Switch 21 Series Limit Switch Buy Online
Series 21 - size 1-1/2" sq X 3-13/16" long w/1/2"-14 NPT conduit outlet. Add 1/2" for bottom conduit hub
Contact Choose One 1 - Single Pole Double Throw 3 - Single Pole Double Throw (c) Latching (Outlet must be 2,4 or 5) 5 - Double Make/Double Break 2 circuit (Z) 6 - Double Make/Double Breake 2 circuit Z Latching (Outlet must be 2,4, or 5)
Sensing Choose One 1 - Standard Range 3/8" 7 - Precision Sensing 1/4"
Outlet Choose One 1 - Behind Sensing area 2 - Left of Sensing Area 3 - Right of Sensing area 4 - Same Side as Sensing Area 6 - Bottom of enclosure
Enclosure Choose One 1 - Brass - coated with flat black lacquer 2 - Stainless Steel 3 - Brass - corrosion resistant coating 4 - Stainless Steel w/corrosion resistant coating
Approvals (Check One ONLY)
3 - UL listed explosion proof for Class I,II,III;Div 1, Groups ABCDEFG; Class I,II,III; Div 3, Groups ABCDFG. Conduit
connected with 18" minimum potted in UL listed leads or cable. Enclosure must be 2 or 4
4 - CSA/FM certified explosion rpoof for Class I,II,III;Div 1, Groups ABCDEFG; Conduit connected, heavy pilot duty with
18" minimum potted-in CSA listed leads or cable. Enclosure must be 2 or 4
5 - Mine Safety Health Admin (MSHA) approved for Explosion Proof, File #X/P-1504-1, X/P-1504-2; 6ft potted-in
SO cable only. Enclosure must be 2, Terminations must be B3.
6 - CSA/FM certified Class I,II,III;Div. 2, Groups ABCDFG; conduit connected, heavy pilot duty with 18" minimum potted-in
CSA listed leads or cable.
7 - CSA certified General Purpose
8 - UL Listed General Purpose
0 - CSA/FM certified Class I,II,III;Div 2 Groups ABCDFG; Terminal Block
A - SAA: Ex s IIC T6 IP65; Class I Zone 1 & 2; Ex s IIC t6 IP65; Class 1 Zone 0; DIP Class II (Must be connected to Ex ia
barrier supply (barrier)). Terminations must be F.
B - SAA: High Temp 350 deg F: Ex s IIC T6 IP65; Class 1 Zone 1&2; Exs IIC T6 IP65; Class 1 Zone 0; DIP Class II (Must
be connected to EX ia supply (barrier)). Terminations must be F.
C - SAA: EX e IIC T6 IP65; Class I Zone 1 (Rated to 275VAC) Terminations must be 00.
Terminations
(choose one only)
00 - Terminal block only (not recommended for underwater use. Approval must be 0, 7 or 8.
Termination A Lead Wires. 16 ga potted-in PVC insulated AWM/TEW stranded lead wires reated at 221 deg F
600V UL/CSA listed
A2 - 36" leads
A3 - 72" leads
A4 - 144" leads
Lengths greater than 144". Specify length in feet
Termination B Cable. 16 ga potted-in SO rubber covered cable rated at 194 deg F. 600V UL/CSA listed
B2 - 36" leads
B3 - 72" leads
B4 - 144" leads
Termination D Male Quick Disconnect only, potted in connector. (CSA requires a ground, Approval must be 7 or 8)
DCA - 3-pin Mini-change type
DCD - 4-pin Mini-change type
DCG - 5-pin Mini-change type
DBA - 3-pin Micro-change type
DBD - 4-pin Micro-change type
DBG - 5-pin Micro-change type
Subsea Underwater Connector
3DD - 3 pin Impulse type certified to not leak underwater (Enclosure must be 2 or 4)
4DD - 4 pin Impulse type certified to not leak underwater (Enclosure must be 2 or 4)
3DE - 3 pin Impulse type certified to not leak under water (Enclosure must be 2 or 4)
4DE - 4 pin Impulse type certified not to leak under water (Enclosure must be 2 or 4)
Termination F 18 ga potted-in teflon insulated leads rated at 482 deg F. 600V UL/CSA listed.
F2 - 36" leads
F3 - 72" leads
F4 - 144" leads
Lengths greater than 144". Specify length in feet.
Enter the following information and click on submit to receive a quote via email:
Email
Company Name
Your Name
Business Type Choose One OEM Systems Integrator Resale End User
Fax Number (optional - enter if you would like a hard copy faxed)
Kim Controls, Industrial Automation Products Inc. 10045 Davenport St. NE Minneapolis, MN 55449 Phone: 763-780-2991 Fax: 763-780-9449 Toll Free: 888-296-1295
Copyright © 2000-2007