Industrial Automation Products Inc.
Search Inventory

 
 
Shop by Category

Go Switch 7G, 7H & 7I Series

Buy Online

Series  

Contact 

Sensing 

Outlet   

Enclosure 

Approvals  (Check One ONLY)

  3 - UL listed explosion proof for Class I,II,III;Div 1, Groups ABCDEFG; Class I,II,III; Div 2, Groups ABCDFG. Conduit

             connected with 18" minimum potted in UL listed leads or cable. Model 73 only.

  4 - CSA/FM certified explosion rpoof for Class I,II,III;Div 1, Groups ABCDEFG; Conduit connected, heavy pilot duty with

            18" minimum potted-in CSA listed leads or cable. Model 73 only.

6 - CSA/FM certified Class I,II,III;Div. 2, Groups ABCDFG; conduit connected, heavy pilot duty with 18" minimum potted-in

           CSA listed leads or cable. Model 73 only.

7 - CSA certified General Purpose

8 - UL Listed General Purpose

9 - CENELEC: EExdllC T6 Zone 1. (EN50 014 & EN50 018, BASEEFA Certificate Ex89C1233X (Model 73 Only)

A - SAA: Ex s IIC T6 IP65; Class I Zone 1 & 2; Ex s IIC t6 IP65; Class 1 Zone 0; DIP Class II (Must be connected to Ex ia

            barrier supply (barrier)). Model 73 only.  Termination must be A.

 

Terminations

(choose one only)

 

Termination A Lead Wires. 18 ga potted-in PVC insulated AWM/TEW stranded lead wires reated at 221 deg F

600V UL/CSA listed

A2 - 36" leads

A3 - 72" leads

A4 - 144" leads

Lengths greater than 144". Specify length in feet

 

Termination B Cable. 18 ga potted-in SO rubber covered cable rated at 194 deg F. 600V UL/CSA listed

B2 - 36" leads

B3 - 72" leads

B4 - 144" leads

Lengths greater than 144". Specify length in feet

 

Termination D Male Quick Disconnect only, potted in connector. (CSA requires a ground, Approval must be 7 or 8)

DCA - 3-pin Mini-change type

DCD - 4-pin Mini-change type

DCG - 5-pin Mini-change type

DBA - 3-pin Micro-change type

DBD - 4-pin Micro-change type

DBG - 5-pin Micro-change type

 

Subsea Underwater Connector

3DD - 3 pin Impulse type certified to not leak underwater (Enclosure must be 2 or 4)

4DD - 4 pin Impulse type certified to not leak underwater (Enclosure must be 2 or 4)

3DE - 3 pin Impulse type certified to not leak under water (Enclosure must be 2 or 4)

4DE - 4 pin Impulse type certified not to leak under water (Enclosure must be 2 or 4)

 

Termination F 18 ga potted-in teflon insulated leads rated at 482 deg F. 600V UL/CSA listed.

F2 - 36" leads

F3 - 72" leads

F4 - 144" leads

Lengths greater than 144". Specify length in feet.

 

Enter the following information and click on submit to receive a quote via email:

Email                   

Company Name  

Your Name         

Business Type     

Fax Number         (optional - enter if you would like a hard copy faxed)