Go Switch 7G, 7H & 7I Series
Buy Online
Series Choose One 7G - 5/8" dia. X 4" Long with 5/8-18 UNF x 1-3/4" Threads and 1/2" -14 NPT Conduit Hub 7H - 5/8" dia X 3-1/4" long 5/8"-18 UNF x 1-3/4" threads. No Conduit Hub. 7I - 1" dia x 5-5/8" long with 1"-14 UNF x 3" threads and 1/2" NPT Conduit Hub
Contact Choose One 1 - Single Pole Double Throw (form C) Hermetically Sealed (7G or 7I only) 2 - Double Pole Double Throw (two form c's)
Sensing Choose One 1 - Standard sensing approx .090" (2.3mm) end sensing.
Outlet Choose One 5 - Bottom of Enclosure
Enclosure Choose One 2 - 303 Stainless Steel (rated 2,000 PSI). Sensing range must be 3. 6 - 316 Stainless Steel (rated 2,000 PSI).
Approvals (Check One ONLY)
3 - UL listed explosion proof for Class I,II,III;Div 1, Groups ABCDEFG; Class I,II,III; Div 2, Groups ABCDFG. Conduit
connected with 18" minimum potted in UL listed leads or cable. Model 73 only.
4 - CSA/FM certified explosion rpoof for Class I,II,III;Div 1, Groups ABCDEFG; Conduit connected, heavy pilot duty with
18" minimum potted-in CSA listed leads or cable. Model 73 only.
6 - CSA/FM certified Class I,II,III;Div. 2, Groups ABCDFG; conduit connected, heavy pilot duty with 18" minimum potted-in
CSA listed leads or cable. Model 73 only.
7 - CSA certified General Purpose
8 - UL Listed General Purpose
9 - CENELEC: EExdllC T6 Zone 1. (EN50 014 & EN50 018, BASEEFA Certificate Ex89C1233X (Model 73 Only)
A - SAA: Ex s IIC T6 IP65; Class I Zone 1 & 2; Ex s IIC t6 IP65; Class 1 Zone 0; DIP Class II (Must be connected to Ex ia
barrier supply (barrier)). Model 73 only. Termination must be A.
Terminations
(choose one only)
Termination A Lead Wires. 18 ga potted-in PVC insulated AWM/TEW stranded lead wires reated at 221 deg F
600V UL/CSA listed
A2 - 36" leads
A3 - 72" leads
A4 - 144" leads
Lengths greater than 144". Specify length in feet
Termination B Cable. 18 ga potted-in SO rubber covered cable rated at 194 deg F. 600V UL/CSA listed
B2 - 36" leads
B3 - 72" leads
B4 - 144" leads
Termination D Male Quick Disconnect only, potted in connector. (CSA requires a ground, Approval must be 7 or 8)
DCA - 3-pin Mini-change type
DCD - 4-pin Mini-change type
DCG - 5-pin Mini-change type
DBA - 3-pin Micro-change type
DBD - 4-pin Micro-change type
DBG - 5-pin Micro-change type
Subsea Underwater Connector
3DD - 3 pin Impulse type certified to not leak underwater (Enclosure must be 2 or 4)
4DD - 4 pin Impulse type certified to not leak underwater (Enclosure must be 2 or 4)
3DE - 3 pin Impulse type certified to not leak under water (Enclosure must be 2 or 4)
4DE - 4 pin Impulse type certified not to leak under water (Enclosure must be 2 or 4)
Termination F 18 ga potted-in teflon insulated leads rated at 482 deg F. 600V UL/CSA listed.
F2 - 36" leads
F3 - 72" leads
F4 - 144" leads
Lengths greater than 144". Specify length in feet.
Enter the following information and click on submit to receive a quote via email:
Email
Company Name
Your Name
Business Type Choose One OEM Systems Integrator Resale End User
Fax Number (optional - enter if you would like a hard copy faxed)
Kim Controls, Industrial Automation Products Inc. 10045 Davenport St. NE Minneapolis, MN 55449 Phone: 763-780-2991 Fax: 763-780-9449 Toll Free: 888-296-1295
Copyright © 2000-2007